Technical Parameters:
- Electric parameters: IEC1009(ENG61009)
- Accord with electric standards: GB16917.1
                                                    □ not prolong
- Leakage action time: G minimum 10ms for prolonging
                                    230V;50HZ 230V/400V
- Rated voltage(Ue): 10,30,300mA 30,300mA
- Rated current : Ac type A type
- Sensitivity: 3
- Alternative level: 10kA
- Rated breaking capacity: 6-40A 6-32A
- Rated current in: C characteristic curve
- Take off the characteristic of deducting: 100A gl(10kA)
- The biggest fuse: According to IEC1008
- The ability of resisting: standard
- The climate condition: IP40 Afer installing
- Grade of shelter of outer cover: Electric:not less than 4000 times(on-off)
- Service life: Mechanism:not less than 20,000 times(on-off)

Mechanical Parameters:
Installation mode: it is installed in the DIN rail 35mm
                              1-25 square mm of wire
Terminal connection ability: Busbar thickness 0.8-2mm
Shell width: 35mm(1P+N)
Main Properties:
- Action funcation has nothing to do with main circuit voltage.
- With midline on-off functions, it is safer and more reliable.
- With double functional connection terminals, it has strong connection ability.
- With contact state indicator, it is easy to recognize the contact situation.
- Different handle colors are used to indicate rated current.
- High breaking ability 10kA.
- With wide range of rated current, it can be used as family main switch.

Technical Specification:
Integrating electric, over loading and short circuit

C properties curve
It is able to prevent from release action caused by the switch operation of electronic equipment.
Specification Rated current( A) Model Model
1P+N surge protection to 250A 6 HK7LE-6/1N/0.03/C HK7LE-6/1N/0.03/C-A
10 HK7LE-10/1N/0.03/C HK7LE-10/1N/0.03/C-A
13 HK7LE-13/1N/0.03/C HK7LE-13/1N/0.03/C-A
16 HK7LE-16/1N/0.03/C HK7LE-16/1N/0.03/C-A
20 HK7LE-20/1N/0.03/C HK7LE-20/1N/0.03/C-A
25 HK7LE-25/1N/0.03/C HK7LE-25/1N/0.03/C-A
32 HK7LE-32/1N/0.03/C HK7LE-32/1N/0.03/C-A
40 HK7LE-40/1N/0.03/C HK7LE-40/1N/0.03/C-A
1P+N surge protection to 3kA 6 HK7LE-6/1N/0.03/C-G HK7LE-6/1N/0.3/C-G
10 HK7LE-10/1N/0.03/C-G HK7LE-10/1N/0.3/C-G
13 HK7LE-13/1N/0.03/C-G HK7LE-13/1N/0.3/C-G
16 HK7LE-16/1N/0.03/C-G HK7LE-16/1N/0.3/C-G
20 HK7LE-20/1N/0.03/C-G HK7LE-20/1N/0.3/C-G
25 HK7LE-25/1N/0.03/C-G HK7LE-25/1N/0.3/C-G
32 HK7LE-32/1N/0.03/C-G HK7LE-32/1N/0.3/C-G
40 HK7LE-40/1N/0.03/C-G HK7LE-40/1N/0.3/C-G

Outer and Mount Dimensions:
HK7LE Leakage Circuit Breakers With Over Current Protenction Dimensions - Leakage Circuit Breakers With Over Current Protenction